Proline Promass Q 500 Coriolis flowmeter

The innovative specialist for challenging applications,

as remote version with up to 4 I/Os

Promass Q 500 provides the highest measurement accuracy for mass flow, volume flow and density. Being the preferred choice for custody transfer applications, it has also been optimized for liquid applications where entrained gas is known to be present. With its innovative remote transmitter Promass Q 500 maximizes installation flexibility and operational safety in demanding environments. Heartbeat Technology ensures compliance and process safety at all times.

Promass Q 500, 8Q5B1H, DN100 4″

Promass Q 500, 8Q5B25, DN25 1″

Promass Q 500, 8Q5B50, DN50 2″

Promass Q 500, 8Q5B80, DN80 3″

Benefits

  • Secured measuring quality – unmatched accuracy of mass flow, volume flow and density
  • Optimized performance for liquids with entrained gas – MFT (Multi-Frequency Technology)
  • Fewer process measuring points – multivariable measurement (flow, density, temperature)
  • Space-saving installation – no in/outlet run needs
  • Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses
  • Reduced complexity and variety – freely configurable I/O functionality
  • Integrated verification – Heartbeat Technology
  • Field of application
    • Measuring principle operates independently of physical fluid properties such as viscosity or density
    • Highest measurement performance for density and challenging applications

    Device properties

    • Mass flow: measured error ±0.05 % (PremiumCal)
    • Density: measured error ±0.2 kg/m3
    • High turndown due to low pressure loss/zero point
    • Remote version with up to 4 I/Os
    • Backlit display with touch control and WLAN access
    • Standard cable between sensor and transmitter
      • Measuring principle operates independently of physical fluid properties such as viscosity or density
      • Highest measurement performance for density and challenging applications

      Device properties

      • Mass flow: measured error ±0.05 % (PremiumCal)
      • Density: measured error ±0.2 kg/m3
      • High turndown due to low pressure loss/zero point
      • Remote version with up to 4 I/Os
      • Backlit display with touch control and WLAN access
      • Standard cable between sensor and transmitter

 

All Spare parts

NrOrder codeSpecification
3171323007Kit power supply, 100-230VAC, Ex

Usage:
Promag/Promass 300/500,
transmitter housing,
electronic compartment.
3171323008Kit power supply, 24VDC, Ex

Usage:
Promag/Promass 300/500,
transmitter housing,
electronic compartment.
3171323009Kit pow.supply,100-230VAC/24VDC, Non-haz

Usage:
Promag/Promass 300/500 digital.
Non-haz, Zone 2,
transmitter housing,
electronic compartment.
4771323012Kit main elec.extend.,Promass500 dig.,Ex

Usage:
transmitter housing,
electronic compartment.
4771323013Kit main elec.extender,500 dig., Non-haz

Usage:
transmitter housing,
electronic compartment.
3671323015Kit ISEM extender, 500 digital, Ex

Usage:
Sensor connection housing.
3971185788Kit T-DAT, 100/300/400/500/500 digital

Usage:
Promag/Promass 100/300/500, 500 digital,
Prosonic Flow E 100, Promag 400(C).
(C) = generation index C.
33XPD0028-ISEM electronic module, Promass 300/500

Usage:
Promass, Cubemass 300/500
For Product
BA8*5B**-; 8*5C**-; O8*5B**-
Integrated ISEM Electronic:
ASensor
BTransmitter
Nominal Diameter:
QAPromass Q DN25-50 1″-2″
QBPromass Q DN80-100 3″-4″
Approval; Transmitter + Sensor:
00Not used
Approval; Transmitter; Sensor:
AANon-hazardous area
BAATEX+IECEx; Z1/21,Ex de; Z1/21, IIB/IIIC
BBATEX+IECEx; Z1/21,Ex de; Z1/21, IIC/IIIC
BCATEX+IECEx; Z1/21,Ex d; Z1/21, IIB/IIIC
BDATEX+IECEx; Z1/21,Ex d; Z1/21, IIC/IIIC
BIATEX+IECEx; Non-haz; Z1/21, IIB/IIIC
BJATEX+IECEx; Non-haz; Z1/21, IIC/IIIC
BLATEX+IECEx; Non-haz; Z2
BMATEX+IECEx; Z2; Z1/21, IIB/IIIC
BNATEX+IECEx; Z2; Z1/21, IIC/IIIC
BSATEX+IECEx; Z2; Z2, IIC
C1CSA C/US; Z1/21,Ex de; Z1/21, IIB/IIIC
C2CSA C/US; Z1/21,Ex de; Z1/21, IIC/IIIC
C3CSA C/US; Z1/21,Ex d; Z1/21, IIB/IIIC
C4CSA C/US; Z1/21,Ex d; Z1/21, IIC/IIIC
C5CSA C/US; Z2; Z1/21, IIB/IIIC
C6CSA C/US; Z2; Z1/21, IIC/IIIC
CCCSA C/US; Cl.I,II,III Div.1, XP; Cl.I, Cl.II,III Div.1, Gr.C-G
CDCSA C/US; Cl.I,II,III Div.1, XP; Cl.I Cl.II,III Div.1, Gr.A-G
CMCSA C/US; Cl.I Div.2, NI, Gr.CD; Cl.I,II,III, Div.1, Gr.C-G
CNCSA C/US; Cl.I Div.2, NI, Gr.A-D; Cl.I,II,III, Div.1, Gr.A-G
CSCSA C/US; Cl.I Div.2,NI; Cl.I Div.2
CZCSA C/US; Z2; Z2, IIC
GAEAC; Z1/21, Ex de; Z1/21, IIB/IIIC
GBEAC; Z1/21, Ex de; Z1/21, IIC/IIIC
GCEAC; Z1/21, Ex d; Z1/21, IIB/IIIC
GDEAC; Z1/21, Ex d; Z1/21, IIC/IIIC
GIEAC; Non-haz; Z1/21, IIB/IIIC
GJEAC; Non-haz; Z1/21, IIC/IIIC
GLEAC; Non-haz; Z2
GMEAC; Z2; Z1/21, IIB/IIIC
GNEAC; Z2; Z1/21, IIC/IIIC
GREAC; Non-hazardous area
GSEAC; Z2; Z2, IIC
MAINMETRO; Z1/21,Ex de; Z1/21,IIB/IIIC
MBINMETRO; Z1/21,Ex de; Z1/21,IIC/IIIC
MCINMETRO; Z1/21,Ex d; Z1/21, IIB/IIIC
MDINMETRO; Z1/21,Ex d; Z1/21, IIC/IIIC
MIINMETRO; Non-haz; Z1/21, IIB/IIIC
MJINMETRO; Non-haz; Z1/21, IIC/IIIC
MLINMETRO; Non-haz; Z2
MMINMETRO; Z2; Z1/21, IIB/IIIC
MNINMETRO; Z2; Z1/21, IIC/IIIC
MSINMETRO; Z2; Z2, IIC
NANEPSI; Z1/21,Ex de; Z1/21,IIB/IIIC
NBNEPSI; Z1/21,Ex de; Z1/21,IIC/IIIC
NCNEPSI; Z1/21,Ex d; Z1/21, IIB/IIIC
NDNEPSI; Z1/21,Ex d; Z1/21, IIC/IIIC
NINEPSI; Non-haz; Z1/21, IIB/IIIC
NJNEPSI; Non-haz; Z1/21, IIC/IIIC
NLNEPSI; Non-haz; Z2
NMNEPSI; Z2; Z1/21, IIB/IIIC
NNNEPSI; Z2; Z1/21, IIC/IIIC
NSNEPSI; Z2; Z2, IIC
Meas.Tube Mat.:
99Special version, TSP-no. to be spec.
LAStainl. steel, cryogenic -196oC/-320oF
SAStainl. steel, not polished
SBStainl. steel, 0.8um, 32u-in mechanical polished
Revision number:
00Not used
>>Test, Certificate:
JPAmbient temperature -50oC/-58oF
JQAmbient temperature sensor -60oC/-76oF, transmitter -50oC/-58oF
3771323010Kit module cartridge, 300/500, Ex

Usage:
transmitter housing,
electronic compartment.
Consists of:
module cartridge incl.
interconnection board.
34XPD0037-I/O module, slot 1, 300/500

Usage:
Proline 300/500
For Product:
AA5*3B**-; 5*5B**-; 8*3B**-; 8*5B**-; O8*3B**; O8*5B**
Output; Input 1:
A14-20mA HART, 4-20mA for WirelessHART (Option BA,BB)
B14-20mA HART Ex-i, 4-20mA Ex-i for WirelessHART (Option CA,CB)
C1PROFIBUS PA, FOUNDATION Fieldbus (für Option GA,SA)
D1PROFIBUS PA Ex-i, FOUNDATION Fieldbus Ex-i (Option HA,TA)
E1PROFIBUS DP (Option LA)
F1Modbus RS485 (Option MA)
G1EtherNet/IP 2-port switch integrated, PROFINET 2-port switch integrated (Option NA,RA)
Revision number:
00Not used
4671323005Kit ISEM ribbon cable, 300/500

Usage:
transmitter housing.
4671323006Kit ISEM ribbon cable, 500 digital

Usage:
Sensor connection housing.
4571323075Kit conn.terminal option A, 300/500, Ex

Usage:
transmitter housing Alu/cast,
connection compartment.
Option A =
HART, PROFIBUS PA, FOUNDATION Fieldbus.
Consists of:
2x connection terminal 2-Pol.,
1x connection terminal 4-Pol.
35XPD0038-I/O module, slot 2/3/4, 300/500

Usage:
Proline 300/500
For Product:
AA5*3B**-; 5*5B**-; 8*3B**-; 8*5B**-; O8*3B**; O8*5B**
Output; Input 2/3/4:
1A4-20mA, Configurable I/O default off, Pulse/freq./switch output, 4-20mA input, Status input (Option B,D,E,I,J)
1B4-20mA Ex-i,Pulse/freq./switch out. Ex-i (Option C,G)
1CPulse output, phase-shifted (Option F) (only for Output; Input: 2/3)
1DRelay (Option H)
Revision number:
00Not used
4571323076Kit conn.terminal option B, 300/500, Ex

Usage:
transmitter housing Alu/cast,
connection compartment.
Option B =
EtherNet, PROFINET.
Consists of:
2x connection terminal 2-Pol.
50XPD0031-Display module, 300/500/DKX001

Usage:
Proline 300/500, DKX001.
For Product:
BA5*5B**-; 8*5B**-
Integrated ISEM Electronic:
ANot used
BSensor
Display; Operation:
F4-line illum.; touch control
G4-line illum.; touch control + WLAN
Revision number:
00Not used
4571327819Kit conn.terminal option C, 300/500, Ex

Usage:
transmitter housing Alu/cast,
connection compartment.
Option C =
PROFIBUS DP, Modbus RS485.
Consists of:
2x connection terminal 2-Pol.,
1x connection terminal 4-Pol.
4571323077Kit terminal option A, 500 dig., Non-haz

Usage:
transmitter housing Alu/polycarbonate,
connection compartment.
Option A =
HART, PROFIBUS PA, FOUNDATION Fieldbus.
Consists of:
1x connection terminal 2-Pol.,
1x connection terminal 3-Pol.,
1x connection terminal 4-Pol.,
1x connection terminal 6-Pol.
4571323078Kit terminal option B, 500 dig., Non-haz

Usage:
transmitter housing Alu/polycarbonate,
connection compartment.
Option B =
EtherNet, PROFINET.
Consists of:
1x connection terminal 3-Pol.,
1x connection terminal 4-Pol.,
1x connection terminal 6-Pol.
4571327820Kit terminal option C, 500 dig., Non-haz

Usage:
transmitter housing Alu/polycarbonate,
connection compartment.
Option C =
PROFIBUS DP, Modbus RS485.
Consists of:
1x connection terminal 2-Pol.,
1x connection terminal 3-Pol.,
1x connection terminal 4-Pol.,
1x connection terminal 6-Pol.
4471323268Kit connection board, Promass 500, Ex

Usage:
Sensor connection housing.
Consists of:
connection board,
O-Ring 26,00×1,50 HNBR.
4471323269Kit connec.board, Promass 500, Ex, -50oC

Usage:
Sensor connection housing.
Consists of:
connection board,
O-Ring 26,00×1,50 FVMQ, -50oC/-58oF.
4471323269Kit connec.board, Promass 500, Ex, -50oC

Usage:
Sensor connection housing.
Consists of:
connection board,
O-Ring 26,00×1,50 FVMQ, -50oC/-58oF.
2071323016Kit cover, sight glass, Alu,Non-haz/Exde

Usage:
Promag/Promass 300,
transmitter housing Alu, Non-haz.
Promag/Promass 300/500,
transmitter housing Alu, Ex.
Consists of:
cover Alu, sight glass,
O-Ring 110.7×3.53 HNBR.
2071323017Kit cover,glass, Alu, -50oC,Non-haz/Exde

Usage:
Promass 300,
transmitter housing Alu, Non-haz.
Promag 500, Promass 300/500,
transmitter housing Alu, Ex.
Consists of:
cover Alu, sight glass,
O-Ring 110,7×3,53 FVMQ, -50oC/-58oF.
2071323017Kit cover,glass, Alu, -50oC,Non-haz/Exde

Usage:
Promass 300,
transmitter housing Alu, Non-haz.
Promag 500, Promass 300/500,
transmitter housing Alu, Ex.
Consists of:
cover Alu, sight glass,
O-Ring 110,7×3,53 FVMQ, -50oC/-58oF.
2071323020Kit cover, sight glass, Alu, Exd

Usage:
Promag/Promass 300/500,
transmitter housing Alu, Ex.
Consists of:
cover Alu, sight glass,
O-Ring 110.7×3.53 HNBR.
2071323021Kit cover, sight glass, Alu, -50oC, Exd

Usage:
Promag 500, Promass 300/500,
transmitter housing Alu, Ex.
Consists of:
cover Alu, sight glass,
O-Ring 110,7×3,53 FVMQ, -50oC/-58oF.
2071323021Kit cover, sight glass, Alu, -50oC, Exd

Usage:
Promag 500, Promass 300/500,
transmitter housing Alu, Ex.
Consists of:
cover Alu, sight glass,
O-Ring 110,7×3,53 FVMQ, -50oC/-58oF.
2071323024Kit cover, sight glass, cast, Ex

Usage:
Promag/Promass 300/500,
transmitter housing cast, Ex.
Consists of:
cover cast, sight glass,
O-Ring 110.7×3.53 HNBR.
2071323025Kit cover, sight glass, cast, -50oC, Ex

Usage:
Promag 500, Promass 300/500,
transmitter housing cast, Ex.
Consists of:
cover cast, sight glass,
O-Ring 110,7×3,53 FVMQ, -50oC/-58oF.
2071323025Kit cover, sight glass, cast, -50oC, Ex

Usage:
Promag 500, Promass 300/500,
transmitter housing cast, Ex.
Consists of:
cover cast, sight glass,
O-Ring 110,7×3,53 FVMQ, -50oC/-58oF.
7071323026Kit cover gasket, sight glass/blind

Usage:
Promag/Promass 300/500,
transmitter housing Alu/cast.
Consists of:
10x O-Ring 110.7×3.53 HNBR.
7071323027Kit cover gasket,sight glass/blind,-50oC

Usage:
Promag 500, Promass 300/500,
transmitter housing Alu/cast,
Consists of:
O-Ring 110,7×3,53 FVMQ, -50oC/-58oF.
7071323027Kit cover gasket,sight glass/blind,-50oC

Usage:
Promag 500, Promass 300/500,
transmitter housing Alu/cast,
Consists of:
O-Ring 110,7×3,53 FVMQ, -50oC/-58oF.
2271323032Kit cover, electronic compart., Alu, Ex

Usage:
Promag/Promass 300/500,
transmitter housing Alu, Ex.
Consists of:
cover Alu,
O-Ring 120,2×3,53 HNBR.
2271323033Kit cover, electr.compart., Alu,-50oC,Ex

Usage:
Promag 500, Promass 300/500,
transmitter housing Alu, Ex.
Consists of:
cover Alu,
O-Ring 120,2×3,53 FVMQ, -50oC/-58oF.
2271323033Kit cover, electr.compart., Alu,-50oC,Ex

Usage:
Promag 500, Promass 300/500,
transmitter housing Alu, Ex.
Consists of:
cover Alu,
O-Ring 120,2×3,53 FVMQ, -50oC/-58oF.
2271323034Kit cover, electronic compart., cast, Ex

Usage:
Promag/Promass 300/500,
transmitter housing cast, Ex.
Consists of:
cover cast,
O-Ring 120,2×3,53 HNBR.
2271323035Kit cover, electr.compart.,cast,-50oC,Ex

Usage:
Promag 500, Promass 300/500,
transmitter housing cast, Ex.
Consists of:
cover cast,
O-Ring 120,2×3,53 FVMQ, -50oC/-58oF.
2271323035Kit cover, electr.compart.,cast,-50oC,Ex

Usage:
Promag 500, Promass 300/500,
transmitter housing cast, Ex.
Consists of:
cover cast,
O-Ring 120,2×3,53 FVMQ, -50oC/-58oF.
7471323036Kit cover gasket, electronic compart.,Ex

Usage:
Promag/Promass 300/500,
transmitter housing Alu/cast, Ex.
Consists of:
10x O-Ring 120,2×3,53 HNBR.
7471323037Kit cover gasket,elect.compart.,-50oC,Ex

Usage:
Promag 500, Promass 300/500,
transmitter housing Alu/cast, Ex.
Consists of:
O-Ring 120,2×3,53 FVMQ, -50oC/-58oF.
7471323037Kit cover gasket,elect.compart.,-50oC,Ex

Usage:
Promag 500, Promass 300/500,
transmitter housing Alu/cast, Ex.
Consists of:
O-Ring 120,2×3,53 FVMQ, -50oC/-58oF.
2371323038Kit cover, wall mount, Alu, Ex

Usage:
Promag/Promass 500,
wall mount transmitter Alu, Ex,
connection compartment.
Consists of:
cover Alu,
O-Ring 88,50×3,53 HNBR.
2371323039Kit cover, wall mount, Alu, -50oC, Ex

Usage:
Promag/Promass 500,
wall mount transmitter Alu, Ex,
connection compartment.
Consists of:
cover Alu,
O-Ring 88,50×3,53 FVMQ, -50oC/-58oF.
2371323039Kit cover, wall mount, Alu, -50oC, Ex

Usage:
Promag/Promass 500,
wall mount transmitter Alu, Ex,
connection compartment.
Consists of:
cover Alu,
O-Ring 88,50×3,53 FVMQ, -50oC/-58oF.
2371323040Kit cover, wall mount, cast, Ex

Usage:
Promag/Promass 500,
wall mount transmitter cast, Ex,
connection compartment.
Consists of:
cover cast,
O-Ring 88,50×3,53 HNBR.
2371323041Kit cover, wall mount, cast, -50oC, Ex

Usage:
Promag/Promass 500,
wall mount transmitter cast, Ex,
connection compartment.
Consists of:
cover cast,
O-Ring 88,50×3,53 FVMQ, -50oC/-58oF.
2371323041Kit cover, wall mount, cast, -50oC, Ex

Usage:
Promag/Promass 500,
wall mount transmitter cast, Ex,
connection compartment.
Consists of:
cover cast,
O-Ring 88,50×3,53 FVMQ, -50oC/-58oF.
7571323042Kit cover gasket, wall mount, Ex

Usage:
Promag/Promass 500,
wall mount transmitter Alu/cast, Ex,
connection compartment.
Consists of:
10x O-Ring 88,50×3,53 HNBR.
7571323043Kit cover gasket, wall mount, -50oC, Ex

Usage:
Promag/Promass 500,
wall mount transmitter Alu/cast, Ex,
connection compartment.
Consists of:
O-Ring 88,50×3,53 FVMQ, -50oC/-58oF.
7571323043Kit cover gasket, wall mount, -50oC, Ex

Usage:
Promag/Promass 500,
wall mount transmitter Alu/cast, Ex,
connection compartment.
Consists of:
O-Ring 88,50×3,53 FVMQ, -50oC/-58oF.
2071384170Kit cover, alu,Promag 400(C),500 digital

Usage:
Promag 400(C) = generation index C,
Promag/Promass 500 digital,
transmitter housing Alu, Ex.
Consists of:
cover Alu complete included
O-Ring 196,44×3,53 VMQ, default and
-50oC/-58oF,
wire with screw lock 1,5×150.
7071278078Kit cover gasket, alu,400(C),500 digital

Usage:
Promag 400(C) = generation index C,
Promag/Promass 500 digital,
transmitter housing Alu, Ex.
Consists of:
10x O-Ring 196,44×3,53 VMQ, default and
-50oC/-58oF.
2471228796Kit cover, remote, Alu

Usage:
Promag 400(C) = generation index C,
Promag 500,
Promag/Promass 500 digital,
sensor connection housing.
Consists of:
cover Alu,
O-Ring 113,90×3,53 HNBR.
2471323050Kit cover, remote, Alu, -50oC

Usage:
Promass 500 digital,
sensor connection housing.
Consists of:
cover Alu,
O-Ring 113,90×3,53 FVMQ, -50oC/-58oF.
2471323050Kit cover, remote, Alu, -50oC

Usage:
Promass 500 digital,
sensor connection housing.
Consists of:
cover Alu,
O-Ring 113,90×3,53 FVMQ, -50oC/-58oF.
7371323051Kit housing gaskets, remote, Alu

Usage:
Promass 500 digital,
sensor connection housing.
Consists of:
O-Ring 113,90×3,53 HNBR for cover,
gasket EPDM for housing/sensor.
7371323052Kit housing gaskets, remote, Alu, -50oC

Usage:
Promass 500 digital,
sensor connection housing.
Consists of:
O-Ring 113,90×3,53 FVMQ for cover,
-50oC/-58oF,
gasket FVMQ for housing/sensor,
-50oC/-58oF.
7371323052Kit housing gaskets, remote, Alu, -50oC

Usage:
Promass 500 digital,
sensor connection housing.
Consists of:
O-Ring 113,90×3,53 FVMQ for cover,
-50oC/-58oF,
gasket FVMQ for housing/sensor,
-50oC/-58oF.
2471323053Kit cover, remote, stainless 1.4301

Usage:
Promass 500,
Promag/Promass 500 digital,
sensor connection housing.
Consists of:
cover stainless 1.4301,
gasket EPDM for cover.
2471323054Kit cover, remote,stainless 1.4301,-50oC

Usage:
Promass 500,
Promass 500 digital,
sensor connection housing.
Consists of:
cover stainless 1.4301,
gasket FVMQ for cover, -50oC/-58oF.
2471323054Kit cover, remote,stainless 1.4301,-50oC

Usage:
Promass 500,
Promass 500 digital,
sensor connection housing.
Consists of:
cover stainless 1.4301,
gasket FVMQ for cover, -50oC/-58oF.
7371323057Kit housing gaskets, remote, stainless

Usage:
Promass 500,
Promass 500 digital,
sensor connection housing.
Consists of:
gasket EPDM for cover,
gasket EPDM for housing/sensor.
7371323058Kit hous.gaskets, remote,stainless,-50oC

Usage:
Promass 500,
Promass 500 digital,
sensor connection housing.
Consists of:
gasket FVMQ for cover, -50oC/-58oF,
gasket FVMQ for housing/sensor,
-50oC/-58oF.
7371323058Kit hous.gaskets, remote,stainless,-50oC

Usage:
Promass 500,
Promass 500 digital,
sensor connection housing.
Consists of:
gasket FVMQ for cover, -50oC/-58oF,
gasket FVMQ for housing/sensor,
-50oC/-58oF.
2471185793Kit cover,ultra compact,stainless 1.4301

Usage:
Promag/Promass 100,
Promag/Promass 500 digital,
sensor connection housing.
Consists of:
cover stainless 1.4301,
gasket EPDM for cover.
2471323060Kit cover, ultra compact, 1.4301, -50oC

Usage:
Promass 500 digital,
sensor connection housing.
Consists of:
cover stainless 1.4301,
gasket FVMQ for cover, -50oC/-58oF.
2471323060Kit cover, ultra compact, 1.4301, -50oC

Usage:
Promass 500 digital,
sensor connection housing.
Consists of:
cover stainless 1.4301,
gasket FVMQ for cover, -50oC/-58oF.
7371185799Kit hous.gaskets,ultra compact,stainless

Usage:
Promass 100,
Promass 500 digital,
sensor connection housing.
Consists of:
gasket EPDM for cover,
gasket EPDM for housing/sensor.
7371323062Kit housing gasket, ultra compact, -50oC

Usage:
Promass 500 digital,
sensor connection housing stainless.
Consists of:
gasket FVMQ for cover, -50oC/-58oF,
gasket FVMQ for housing/sensor,
-50oC/-58oF.
7371323062Kit housing gasket, ultra compact, -50oC

Usage:
Promass 500 digital,
sensor connection housing stainless.
Consists of:
gasket FVMQ for cover, -50oC/-58oF,
gasket FVMQ for housing/sensor,
-50oC/-58oF.
2471323063Kit cover, remote, cast, Ex

Usage:
Promag/Promass 500,
Promag/Promass 500 digital,
sensor connection housing.
Consists of:
cover cast,
O-Ring 120,2×3,53 HNBR.
2471323064Kit cover, remote, cast, -50oC, Ex

Usage:
Promass 500,
Promass 500 digital,
sensor connection housing.
Consists of:
cover cast,
O-Ring 120,2×3,53 FVMQ, -50oC/-58oF.
2471323064Kit cover, remote, cast, -50oC, Ex

Usage:
Promass 500,
Promass 500 digital,
sensor connection housing.
Consists of:
cover cast,
O-Ring 120,2×3,53 FVMQ, -50oC/-58oF.
7371323065Kit housing gaskets, remote, cast, Ex

Usage:
Promass 500,
Promass 500 digital,
sensor connection housing.
Consists of:
O-Ring 120,2×3,53 HNBR for cover,
O-Ring 88,50×3,53HNBR for housing/sensor
7371323066Kit housing gaskets,remote,cast,-50oC,Ex

Usage:
Promass 500,
Promass 500 digital,
sensor connection housing.
Consists of:
O-Ring 120,2×3,53 FVMQ for cover,
-50oC/-58oF,
O-Ring 88,50×3,53 FVMQ for hous./sensor,
-50oC/-58oF.
7371323066Kit housing gaskets,remote,cast,-50oC,Ex

Usage:
Promass 500,
Promass 500 digital,
sensor connection housing.
Consists of:
O-Ring 120,2×3,53 FVMQ for cover,
-50oC/-58oF,
O-Ring 88,50×3,53 FVMQ for hous./sensor,
-50oC/-58oF.
7171323071Kit interface gaskets, Promass 300/500

Usage:
transmitter housing/sensor or
transmitter housing/wall mount.
Consists of:
5x O-Ring 88,50×3,53 HNBR for
interface.
7171323072Kit interf.gaskets,Promass 300/500,-50oC

Usage:
transmitter housing/sensor or
transmitter housing/wall mount.
Consists of:
O-Ring 88,50×3,53 FVMQ for
interface, -50oC/-58oF.
7171323072Kit interf.gaskets,Promass 300/500,-50oC

Usage:
transmitter housing/sensor or
transmitter housing/wall mount.
Consists of:
O-Ring 88,50×3,53 FVMQ for
interface, -50oC/-58oF.
1171323081Kit protective cover option A,300/500,Ex

Usage:
transmitter housing Alu/cast,
connection compartment.
Option A =
HART, PROFIBUS PA, PROFIBUS DP,
Modbus RS485, FOUNDATION Fieldbus.
Consists of:
Connection compartment protective cover,
display carrier, 2x screw M4x10.
1171323082Kit protective cover option B,300/500,Ex

Usage:
transmitter housing Alu/cast,
connection compartment.
Option B =
EtherNet, PROFINET.
Consists of:
Connection compartment protective cover,
display carrier, 2x screw M4x10.
1371276494Kit securing clamp, screw

Usage: Promass 100, Promag 100,
Prosonic Flow E 100/E Heat,
CNGmass, LPGmass, LNGmass.
Sensor housing: Promag 400(C),
(C) = generation index C,
Promag/Promass 500,
Promag/Promass 500 digital.
Consists of:
cover clamp, screw M4x16.
8271228792Kit display protec., 400(C)/500 digital

Usage:
Promag 400(C) = generation index C,
Promag/Promass 500 digital,
transmitter housing.
Consists of:
display protection 1.4301,
installation material.
8771343504Kit weather protection cover,500 digital

Usage:
Promag/Promass 500 digital,
transmitter housing.
Consists of:
weather protection cover 4404.
8771343505Kit weather protection cover, 300/500

Usage:
Promag/Promass 300/500,
transmitter housing.
Consists of:
weather protection cover 4404,
installation material.
71346427Pipe Mounting kit Transmitter 500digital
71346428Pipe Mounting kit Transmitter 500
71351317Kit wireless antenna extended range

Consists of:
Connection cable in the transmitter,
Ex cable entry for antenna,
1.5m cable,
antenna,
angle with union nut.
8X5BXX-Transmitter Promass 500, 8X5BXX

With an integrated web server.

 

Approval; Transmitter; Sensor:
AANon-hazardous area
BAATEX+IECEx; Z1/21,Ex de; Z1/21, IIB/IIIC
BBATEX+IECEx; Z1/21,Ex de; Z1/21, IIC/IIIC
BCATEX+IECEx; Z1/21,Ex d; Z1/21, IIB/IIIC
BDATEX+IECEx; Z1/21,Ex d; Z1/21, IIC/IIIC
BIATEX+IECEx; Non-haz; Z1/21, IIB/IIIC
BJATEX+IECEx; Non-haz; Z1/21, IIC/IIIC
BLATEX+IECEx; Non-haz; Z2
BMATEX+IECEx; Z2; Z1/21, IIB/IIIC
BNATEX+IECEx; Z2; Z1/21, IIC/IIIC
BSATEX+IECEx; Z2; Z2, IIC
C1CSA C/US; Z1/21,Ex de; Z1/21, IIB/IIIC
C2CSA C/US; Z1/21,Ex de; Z1/21, IIC/IIIC
C3CSA C/US; Z1/21,Ex d; Z1/21, IIB/IIIC
C4CSA C/US; Z1/21,Ex d; Z1/21, IIC/IIIC
C5CSA C/US; Z2; Z1/21, IIB/IIIC
C6CSA C/US; Z2; Z1/21, IIC/IIIC
CCCSA C/US; Cl.I,II,III Div.1, XP; Cl.I, Cl.II,III Div.1, Gr.C-G
CDCSA C/US; Cl.I,II,III Div.1, XP; Cl.I Cl.II,III Div.1, Gr.A-G
CMCSA C/US; Cl.I Div.2, NI, Gr.CD; Cl.I,II,III, Div.1, Gr.C-G
CNCSA C/US; Cl.I Div.2, NI, Gr.A-D; Cl.I,II,III, Div.1, Gr.A-G
CSCSA C/US; Cl.I Div.2,NI; Cl.I Div.2
CZCSA C/US; Z2; Z2, IIC
GAEAC; Z1/21, Ex de; Z1/21, IIB/IIIC
GBEAC; Z1/21, Ex de; Z1/21, IIC/IIIC
GCEAC; Z1/21, Ex d; Z1/21, IIB/IIIC
GDEAC; Z1/21, Ex d; Z1/21, IIC/IIIC
GIEAC; Non-haz; Z1/21, IIB/IIIC
GJEAC; Non-haz; Z1/21, IIC/IIIC
GLEAC; Non-haz; Z2
GMEAC; Z2; Z1/21, IIB/IIIC
GNEAC; Z2; Z1/21, IIC/IIIC
GREAC; Non-hazardous area
GSEAC; Z2; Z2, IIC
MAINMETRO; Z1/21,Ex de; Z1/21,IIB/IIIC
MBINMETRO; Z1/21,Ex de; Z1/21,IIC/IIIC
MCINMETRO; Z1/21,Ex d; Z1/21, IIB/IIIC
MDINMETRO; Z1/21,Ex d; Z1/21, IIC/IIIC
MIINMETRO; Non-haz; Z1/21, IIB/IIIC
MJINMETRO; Non-haz; Z1/21, IIC/IIIC
MLINMETRO; Non-haz; Z2
MMINMETRO; Z2; Z1/21, IIB/IIIC
MNINMETRO; Z2; Z1/21, IIC/IIIC
MSINMETRO; Z2; Z2, IIC
NANEPSI; Z1/21,Ex de; Z1/21,IIB/IIIC
NBNEPSI; Z1/21,Ex de; Z1/21,IIC/IIIC
NCNEPSI; Z1/21,Ex d; Z1/21, IIB/IIIC
NDNEPSI; Z1/21,Ex d; Z1/21, IIC/IIIC
NINEPSI; Non-haz; Z1/21, IIB/IIIC
NJNEPSI; Non-haz; Z1/21, IIC/IIIC
NLNEPSI; Non-haz; Z2
NMNEPSI; Z2; Z1/21, IIB/IIIC
NNNEPSI; Z2; Z1/21, IIC/IIIC
NSNEPSI; Z2; Z2, IIC
Power Supply:
9Special version, TSP-no. to be spec.
D24VDC
E100-230VAC
I100-230VAC/24VDC
Output; Input 1:
99Special version, TSP-no. to be spec.
BA4-20mA HART
CA4-20mA HART Ex-i passive
GAPROFIBUS PA
HAPROFIBUS PA Ex-i
LAPROFIBUS DP
MAModbus RS485
NAEtherNet/IP 2-port switch integrated
RAPROFINET 2-port switch integrated
SAFOUNDATION Fieldbus
TAFOUNDATION Fieldbus Ex-i
Output; Input 2:
9Special version, TSP-no. to be spec.
AW/o;
B4-20mA
C4-20mA Ex-i passive
DConfigurable I/O default off
EPulse/freq./switch output
FPulse output, phase-shifted
GPulse/freq./switch output Ex-i passive
HRelay
I4-20mA input
JStatus input
Output; Input 3:
9Special version, TSP-no. to be spec.
AW/o;
B4-20mA
C4-20mA Ex-i passive
DConfigurable I/O default off
EPulse/freq./switch output
FPulse output, phase-shifted
GPulse/freq./switch output Ex-i passive
HRelay
I4-20mA input
JStatus input
Output; Input 4:
9Special version, TSP-no. to be spec.
AW/o;
B4-20mA
C4-20mA Ex-i passive
DConfigurable I/O default off
Epulse/freq./switch output
GPulse/freq./switch output Ex-i passive
HRelay
I4-20mA input
JStatus input
Display; Operation:
9Special version, TSP-no. to be spec.
F4-line illum.; touch control
G4-line illum.; touch control + WLAN
Integrated ISEM Electronic:
9Special version, TSP-no. to be spec.
ASensor
BTransmitter
Transmitter Housing:
9Special version, TSP-no. to be spec.
AAlu, coated
LCast, stainless
Cable, Sensor Connection:
9Special version, TSP-no. to be spec.
ANot used
B20m/60ft digital
E….. m digital
F….. ft digital
Electrical Connection:
3Thread M20 + 1x plug 7/8″
4Thread G1/2 + 1x plug 7/8″
5Thread NPT1/2 + 1x plug 7/8″
9Special version, TSP-no. to be spec.
AGland M20
BThread M20
CThread G1/2
DThread NPT1/2
LThread NPT1/2 + 1x plug M12x1
MGland M20 + 1x plug 7/8″
NGland M20 + 1x plug M12x1
PThread G1/2 + 1x plug M12x1
RGland M20 + 2x plug M12x1
SThread NPT1/2 + 2x plug M12x1
TThread G1/2 + 2x plug M12x1
UThread M20 + 1x plug M12x1
VThread M20 + 2x plug M12x1
Upgrade Kit:
AANot used
Existing Product:
QAPromass Q DN25-50 1″-2″
QBPromass Q DN80-100 3″-4″
Existing Meas. Tube:
99Special version, TSP-no. to be spec.
LAStainl. steel, cryogenic -196oC/-320oF
SAStainl. steel, not polished
SBStainl. steel, 0.8um, 32u-in mechanical polished
Device Model:
A11
>Operation Language Display:
AAEnglish
ABGerman
ACFrench
ADSpanish
AEItalian
AFDutch
AGPortuguese
AHPolish
AIRussian
AJTurkish
AKChinese simplified
ALJapanese
AMKorean
AN*Arabian
AOBahasa
AP*Thai
AQVietnamese
ARCzech
ATSwedish
>>Application Package:
E9Special version, TSP-no. to be spec.
EAExtended HistoROM
EBHeartbeat Verification + Monitoring
EDConcentration
ELOPC-UA server
>>Service:
I8Product documentation on CD
I9Special version, TSP-no. to be spec.
>>Test, Certificate:
JPAmbient temperature -50oC/-58oF
K9Special version, TSP-no. to be spec.
>>Additional Approval:
L9Special version, TSP-no. to be spec.
LASIL
>>Accessory Mounted:
N9Special version, TSP-no. to be spec.
NBAdapter RJ45 M12 (service interface)
>>Accessory Enclosed:
P7Pipe mounting kit
P8Wireless antenna for extended range
P9Special version, TSP-no. to be spec.
PBWeather protection cover
PVDisplay protection
>Firmware Version:
7001.01.zz, Modbus RS485, DevRev01
7101.01.zz, HART, DevRev01
7201.00.zz, PROFIBUS PA
7301.00.zz, PROFINET
7401.00.zz, FOUNDATION Fieldbus
7501.00.zz, PROFIBUS DP, DevRev01
7601.00.zz, Modbus RS485
7701.00.zz, EtherNet/IP
7801.00.zz, HART, DevRev01
>>Marking:
Z1Tagging (TAG), see additional spec.
Z2Bus address, see additional spec.
DK8012-Promass 500, sensor cable set

Connection Cable (analog
and digital) between Sensor Junction
Housing and Transmitter for Remote
Devices of Proline 500.
Approval; Transmitter; Sensor:
AANon-hazardous area
BAATEX+IECEx; Z1/21,Ex de; Z1/21, IIB/IIIC
BBATEX+IECEx; Z1/21,Ex de; Z1/21, IIC/IIIC
BCATEX+IECEx; Z1/21,Ex d; Z1/21, IIB/IIIC
BDATEX+IECEx; Z1/21,Ex d; Z1/21, IIC/IIIC
BIATEX+IECEx; Non-haz; Z1/21, IIB/IIIC
BJATEX+IECEx; Non-haz; Z1/21, IIC/IIIC
BLATEX+IECEx; Non-haz; Z2
BMATEX+IECEx; Z2; Z1/21, IIB/IIIC
BNATEX+IECEx; Z2; Z1/21, IIC/IIIC
BSATEX+IECEx; Z2; Z2, IIC
C1CSA C/US; Z1/21,Ex de; Z1/21, IIB/IIIC
C2CSA C/US; Z1/21,Ex de; Z1/21, IIC/IIIC
C3CSA C/US; Z1/21,Ex d; Z1/21, IIB/IIIC
C4CSA C/US; Z1/21,Ex d; Z1/21, IIC/IIIC
C5CSA C/US; Z2; Z1/21, IIB/IIIC
C6CSA C/US; Z2; Z1/21, IIC/IIIC
CCCSA C/US; Cl.I,II,III Div.1, XP; Cl.I, Cl.II,III Div.1, Gr.C-G
CDCSA C/US; Cl.I,II,III Div.1, XP; Cl.I Cl.II,III Div.1, Gr.A-G
CMCSA C/US; Cl.I Div.2, NI, Gr.CD; Cl.I,II,III, Div.1, Gr.C-G
CNCSA C/US; Cl.I Div.2, NI, Gr.A-D; Cl.I,II,III, Div.1, Gr.A-G
CSCSA C/US; Cl.I Div.2,NI; Cl.I Div.2
CZCSA C/US; Z2; Z2, IIC
GAEAC; Z1/21, Ex de; Z1/21, IIB/IIIC
GBEAC; Z1/21, Ex de; Z1/21, IIC/IIIC
GCEAC; Z1/21, Ex d; Z1/21, IIB/IIIC
GDEAC; Z1/21, Ex d; Z1/21, IIC/IIIC
GIEAC; Non-haz; Z1/21, IIB/IIIC
GJEAC; Non-haz; Z1/21, IIC/IIIC
GLEAC; Non-haz; Z2
GMEAC; Z2; Z1/21, IIB/IIIC
GNEAC; Z2; Z1/21, IIC/IIIC
GREAC; Non-hazardous area
GSEAC; Z2; Z2, IIC
MAINMETRO; Z1/21,Ex de; Z1/21,IIB/IIIC
MBINMETRO; Z1/21,Ex de; Z1/21,IIC/IIIC
MCINMETRO; Z1/21,Ex d; Z1/21, IIB/IIIC
MDINMETRO; Z1/21,Ex d; Z1/21, IIC/IIIC
MIINMETRO; Non-haz; Z1/21, IIB/IIIC
MJINMETRO; Non-haz; Z1/21, IIC/IIIC
MLINMETRO; Non-haz; Z2
MMINMETRO; Z2; Z1/21, IIB/IIIC
MNINMETRO; Z2; Z1/21, IIC/IIIC
MSINMETRO; Z2; Z2, IIC
NANEPSI; Z1/21,Ex de; Z1/21,IIB/IIIC
NBNEPSI; Z1/21,Ex de; Z1/21,IIC/IIIC
NCNEPSI; Z1/21,Ex d; Z1/21, IIB/IIIC
NDNEPSI; Z1/21,Ex d; Z1/21, IIC/IIIC
NINEPSI; Non-haz; Z1/21, IIB/IIIC
NJNEPSI; Non-haz; Z1/21, IIC/IIIC
NLNEPSI; Non-haz; Z2
NMNEPSI; Z2; Z1/21, IIB/IIIC
NNNEPSI; Z2; Z1/21, IIC/IIIC
NSNEPSI; Z2; Z2, IIC
Integrated ISEM Electronic:
ASensor
BTransmitter
Existing Sensor Junction Housing:
9Special version, TSP-no. to be spec.
AAlu, coated
BStainless
CUltra-compact hygienic, stainless
LCast, stainless
Cable, Sensor Connection:
15m/15ft coil and signal cable
210m/30ft coil and signal cable
320m/60ft coil and signal cable
9Special version, TSP-no. to be spec.
A***option not used A
B20m/60ft digital
E….. m digital
F….. ft digital
>>Test, Certificate:
JPAmbient temperature sensor -50oC/-58oF
JQ*Ambient temperature sensor -60oC/-76oF, transmitter -50oC/-58oF
K9Special version, TSP-no. to be spec.
XPRFID-Spare RFID TAG

Consists of:
RFID TAG, fixing wire, crimp sleeve.
Approval:
AANon-hazardous area
BAATEX
CACSA
IAIEC Ex
MAINMETRO
NANEPSI
Identification:
1Serial number entry
DK8003-Promass sensor, heating jacket, DK8003

Heating medium (e.g. water, steam)
Nominal Diameter:
1HDN100 4″
25DN25 1″
50DN50 2″
80DN80 3″
Sensor:
QAPromass Q
Heating Jacket Material:
SStainl. Steel
Heating Fluid Connection:
RBG1/2″ internal thread
RCG3/4″ internal thread
RDNPT1/2″ internal thread
RENPT3/4″ internal thread
RF1/2″ Cl. 150 RF, flange ASME B16.5
RG1/2″ Cl. 300 RF, flange ASME B16.5
RHDN15 PN40, flange EN1092-1-B1
Device Model:
A11
>>Test, Certificate:
JBPressure test, internal procedure pressure retaining parts inspection certificate
JC3.1 material certificate EN10204-3.1 inspection certificate
More Products  Proline Promag P 300 Electromagnetic flowmeter

Promass Q 500, 8Q5B1H, DN100 4″
Promass Q 500, 8Q5B25, DN25 1″
Promass Q 500, 8Q5B50, DN50 2″
Promass Q 500, 8Q5B80, DN80 3″

https://www.endress.com/en/Field-instruments-overview/Flow-measurement-product-overview/Coriolis-flowmeter-Promass-Q500

Leave a Reply