Rosemount 0078 sensor with Thermowell Overview

 * Discontinued in North America and Latin America *

As an industry-standard Pt100-385 sensor, the Rosemount 78 RTD Temperature Sensor offers single or dual element configuration with Class A or B accuracy. The wire-wound design is a great solution for applications that require high accuracy or high temperature. A variety of options for enclosures and connection heads are available, as well as calibration options, including Class A sensor calibration or Callendar-Van Dusen constants.

 

Rosemount Thermowell 0078 Specifications

DOWNLOAD FULL SPECS

Lead Wires

For single and dual-element, PTFE-insulated, nickel-coated, 22-gauge stranded copper wire; for single-element high-temperature, see full specs

Time Constant / Response

For single and dual-element, 4 seconds maximum required to reach 63.2% sensor response in water flowing at 3 ft/s (0.91 m/s) For single-element high-temperature, see full specs

Stability

±0.05% maximum ice-point resistance shift following 1,000 hours at 400 °C (752 °F)

Insulation Resistance

500 x 10^6 ohms minimum insulation resistance when measured at 500 Vdc at room temperature (20 °C [68 °F])

Calibration Options

IEC 751 Class A accuracy; Calibration schedule or customer-specified calibration range, both with Callendar-van Dusen constants

Stability

±0.05% maximum ice-point resistance shift following 1,000 hours at 400 °C (752 °F)

More Products  Rosemount 644 Temperature Transmitter

Insulation Resistance

500 x 10^6 ohms minimum insulation resistance when measured at 500 Vdc at room temperature (20 °C [68 °F])

Calibration Options

IEC 751 Class A accuracy; Calibration schedule or customer-specified calibration range, both with Callendar-van Dusen constants

 

Rosemount Thermowell 0078 Features

  • Wire-wound design for applications subjected to high temperatures or requiring high accuracy or dual elements
  • Covers temperatures from –328 to 1112°F (–200 to 600°C) for application durability
  • Offers a range of enclosure and connection head options to meet diverse application requirements
  • Available in capsule, general purpose, spring-loaded and bayonet spring-loaded design for adaptability
  • Optional Class A accuracy for critical temperature measurement points
  • Callendar-Van Dusen constants allow user to match the sensor to the transmitter for notable performance improvement
  • Thermowell available in a variety of materials and process connections for protection from corrosive environments
  • Global hazardous location approvals meet local requirements